Available WQ |
. |
Accepts ‘XP’ |
Internal data |
Logs data with |
| . |
Application / use for: |
sensor ports** |
sensors |
logging |
RuggedReader® |
| Profiler |
Profiling, dip and sample |
4 |
-- |
-- |
Yes |
| Profiler XP |
Profiling, dip and sample |
4 |
Yes |
-- |
Yes |
| Professional |
Data logging and/or profiling |
4 |
-- |
Yes |
Yes |
| Professional XP |
Data logging and/or profiling |
4 |
Yes |
Yes |
Yes |
| LTS |
Data logging, vertical profiling |
1 |
-- |
Yes |
Yes |
 |
| General |
| Dimensions |
47 mm (1.85 in) OD, 57.7 cm (22.7 in) long
|
|
with RDO® sensor: 88.4 mm (3.48 in) OD, 57.7 cm (22.7 in) long |
| . |
RDO® sensor adapter only: 88.4mm (3.5 in) OD, 20.3 cm (8.0 in) long |
| Weight |
1.9 Kg (4.2 lbs) |
| Wetted materials |
PVC, 316L stainless steel, Acetal, Viton®, nylon, FEP* or polyurethane (cable) |
| Water tightness rating |
Housing (not including sensors): up to 2500 psi (1200m / 1600 ft) / Battery compartment: IP67 without the battery cover or cable attached! |
| Output options |
SDI-12 (optional with SDI-12 adapter), ASCII streaming mode or binary command |
| Internal Power |
2 internal user-replaceable D batteries (alkaline or high-power lithium) |
| . |
RDO® requires 2 lithium batteries or external power |
| External Power |
9-12V DC |
 |
| Standard Sensors |
| . |
Accuracy |
Range |
Depth Rating |
Response Time (T90) |
Methodology |
| Barometric Pressure |
± 0.3% FS |
0 – 16.5 psia |
Meets highest rating |
< 30 sec per 30m (100 ft) cable |
. |
| Temperature |
± 0.1°C |
-5°C – 50°C |
Meets highest rating |
< 30 sec |
EPA 170.1 |
Level
Depth, Pressure |
± 0.05% FS |
15 psi |
11m / 35 ft |
In thermal equilibrium: Instantaneous |
. |
| . |
. |
30 psi |
21m / 69 ft |
In thermal change |
. |
| . |
. |
100 psi |
70m / 231 ft |
Instantaneous to ± 2% FS, |
. |
| . |
. |
300 psi |
210m / 692 ft |
30 – 60 min to ± 0.1% FS, |
. |
| . |
. |
. |
. |
1.5 – 2 hr to ± 0.05% FS |
. |
| pH (single or pH/ORP combo) |
± 0.1 pH units |
0 – 12 pH units |
246m / 807 ft |
< 15 sec, pH 7 to pH 4 |
Std.Mthds. 4500-H+, EPA 150.2 |
| ORP (single or pH/ORP combo) |
± 4.0 mV |
± 1400 mV |
246m / 807 ft |
< 15 sec |
Std.Mth ds. 2580 |
| Dissolved Oxygen |
. |
. |
. |
. |
. |
| RDO® (Optical D.O.) |
± 0.1 mg/L |
0 – 10 mg/L |
Meets highest rating |
O2 increasing, 16 seconds |
ASTM #D888-05 Method C |
| . |
± 0.2 mg/L |
10 – 20 mg/L |
Meets highest rating |
O2 decreasing ,45 seconds |
ASTM #D888-05 Method C |
| Clark electrode |
± 0.2 mg/L |
0 – 20 mg/L |
246m / 807ft |
1-mil membrane: 1–2 min@25°C |
Std.Mthds. 4500-O G, EPA 360.1 |
| . |
± 1% |
0 – 200% saturation |
246m / 807ft |
2-mil membrane: 90 sec–3 min |
Std.Mthds. 4500-O G, EPA 360.1 |
| Conductivity |
. |
. |
. |
. |
. |
| Low |
± 0.5% or 2 µS/cm |
5 – 20,000 µS/cm |
Meets highest rating |
Instantaneous |
Std.Mthds. 2510, EPA 120.1 |
| High |
± 0.5% + 2 µS/cm |
150 – 112,000 µS/cm*** |
Meets highest rating |
Instantaneous |
Std.Mthds. 2510, EPA 120.1 |
 |
| Extended Parameter (XP) Sensors |
| . |
Accuracy |
Range |
Depth Rating |
Response Time (T90) |
Methodology |
| Turbidity |
± 5% or 2 NTU/FNU |
0 – 2000 NTU/FNU |
246m / 807 ft |
Instantaneous (5 sec for first reading) |
ISO 7027 |
| Nitrate (NO3–) |
± 10% |
0.14 – 14000 ppm N |
14m / 46 ft |
< 60 sec (T98), 1.4 to 14 ppm N |
Std.Mthds. 4500-NO3 D |
| Ammonium (NH4+) |
± 10% |
0.14 – 14000 ppm N |
14m / 46 ft |
< 60 sec (T98), 1.4 to 14 ppm N |
Std.Mthds. 4500-NH3 D, EPA 350.3 |
| Chloride (Cl-) |
± 15% |
0.35 – 35500 ppm Cl |
70m / 231 ft |
< 60 sec (T98), 3.54 to 35.45 ppm Cl |
. |
 |
| Logging |
| Data Logging |
16 programmable tests (defined, scheduled to run or stored) / Logging Modes: Linear, Linear Average, Event |
| Memory |
4 MB (1,000,000 individual readings) |
| SDI-12 |
Optional with SDI-12 adapter |
 |
| Battery Life Estimates (assuming a 15-minute sampling interval and 20°C) |
| Battery Type |
Sensors |
Total Data Records |
Hours |
Days |
Months |
| 2 D-sized lithium batteries |
Wiper, Temp, Pressure, Baro, Turb, RDO, pH, Cond |
121,760 |
8,117 |
338 |
11 |
| 2 D-sized lithium batteries |
Wiper, Temp, Pressure, Baro, Turb, DO, pH/ORP, Cond |
134,110 |
8,941 |
373 |
12 |
| 2 D-sized alkaline batteries |
Wiper, Temp, Pressure, Baro, Turb, DO, pH/ORP, Cond |
69,514 |
4,634 |
193 |
6 |
 |
* No anode or cathode to scrub or clean.
** Available water quality sensor ports. TROLL® 9500 LTS version supports Level, Temperature, and one water quality Sensor.
*** Full operating range 70 µS/cm - 200,000 µS/cm; typical accuracy from 70 to 150 µS/cm and from 112,000 to 200,000 µS/cm: ± 2% + 4 µS/cm
Twist-Lock Cables
|
| Connector* |
Twist-Lock connector OR stripped & tinned wire |
| Number of conductors |
6 |
| Internal Conductor Material |
Polypropylene |
| Diameter |
6.7mm (0.265”) |
| Break strength |
127 kg (280 lbs) |
| Cable Types |
Vented or Non-Vented Polyurethane
Vented or Non-Vented Halogen-Free Polyurethane - LSZH rated
Vented FEP (Generic Teflon®) |
 |
| Warranty |
The TROLL® 9500 and all sensors (excluding RDO® and ISE sensors) come with a one-year warranty.
|
Warranty on RDO® sensor is 3 years. ISE sensors 90 days.
|
Standard Twist-Lock cables include a one-year warranty. RuggedTwist-Lock cables 2 years.
|
 |
Minimum System Requirements: 400MHz Pentium® II, 128MB RAM, 100MB free disk space, Internet
Explorer® 5.0 or higher, Windows® 2000 Professional SP2 or better, or Windows® XP Professional SP1 or better |

Need more information?
View TROLL® 9500 brochure (pdf)
Tech Note - Read about the accuracy and precision of the Turbidity sensor (pdf)
Get details on battery-powered stirrer for TROLL® 9500 (pdf)
Download Quick-Calibration Specifications (pdf)
Download a copy of the Sensor Summary document
|